Back to top
08045804815
Send SMS Send Inquiry


ScoreFlex Nc Ptca Balloon

ScoreFlex Nc Ptca Balloon
ScoreFlex Nc Ptca Balloon

ScoreFlex Nc Ptca Balloon Specification

  • Features
  • Scoring Element for Precise Dilatation, Non-Compliant Design, Versatile Lesion Modification
  • Function
  • Dilatation of coronary artery stenosis and lesion modification before stent placement
  • Accuracy
  • Precise Lesion Dilatation
  • Storage Instructions
  • Store in Cool, Dry Place
  • Instruments Type
  • Interventional Cardiology Device
  • Measurement Range
  • Balloon Diameter: 1.50 mm - 4.00 mm; Length: 6 mm - 30 mm
  • Shelf Life
  • 2-3 Years
  • Usage Type
  • Disposable, Single Use
  • Equipment Type
  • PTCA Balloon Catheter
  • Material
  • Polyamide (Nylon)
  • Condition
  • New
  • Technology
  • Non-Compliant (NC) Scoring Balloon
  • Portable
  • Yes
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent
  • Operating Type
  • Manual
  • Use
  • Coronary Angioplasty (PTCA)
  • Dimension (L*W*H)
  • Varies by Balloon Size
  • Weight
  • Lightweight, Single-use
  • Color
  • Transparent with Radiopaque Markers
  • Balloon Material
  • Nylon
  • Catheter Length
  • 142 cm (standard)
  • Rated Burst Pressure (RBP)
  • Up to 20 atm
  • Scoring Element
  • Integrated spiral scoring wire
  • Packaging
  • Individually packed, sterile pouch
  • Compliance
  • Non-Compliant (minimal dilation beyond rated size)
  • Shaft Design
  • Rapid Exchange (Rx)
  • Marker Bands
  • Dual platinum-iridium radiopaque markers
  • Hub Connector
  • Universal Luer Lock
  • Recommended Guidewire
  • 0.014 in (0.36 mm)
  • Crossing Profile
  • Low-profile for easy lesion access
  • Sterility
  • Yes, EO Sterilized
 

ScoreFlex Nc Ptca Balloon Trade Information

  • Minimum Order Quantity
  • 100 Packs
  • FOB Port
  • AHMEDABAD
  • Payment Terms
  • Paypal, Cash Advance (CA), Cash in Advance (CID), Letter of Credit at Sight (Sight L/C), Letter of Credit (L/C)
  • Delivery Time
  • 3 Days
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Box
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
 

About ScoreFlex Nc Ptca Balloon

The ScoreFlex NC PTCA Balloon is a specialized medical device used in Percutaneous Transluminal Coronary Angioplasty (PTCA) procedures, which are commonly performed to treat coronary artery disease (CAD). This non-compliant (NC) balloon catheter is designed for precise and controlled dilation of narrowed or blocked coronary arteries.

The ScoreFlex NC PTCA Balloon stands out for its high-pressure capabilities and exceptional performance in coronary interventions. It is designed to withstand higher inflation pressures compared to standard balloons, which allows it to effectively open up even heavily calcified or resistant lesions. This feature makes it an ideal choice for complex coronary interventions where other balloons may not achieve the desired result.

Made from high-quality materials, the ScoreFlex balloon features an innovative scoring technology on its outer surface. These small, diamond-coated elements help to score or fracture the plaque during inflation, facilitating the expansion of the artery and improving blood flow. This scoring mechanism is particularly effective in tough or fibrotic lesions, ensuring a more effective and durable outcome.

The ScoreFlex NC PTCA Balloon is equipped with a precise inflation control system, allowing healthcare professionals to monitor and adjust the pressure with accuracy during the procedure. Its design ensures a smooth and reliable performance, contributing to a safer, more effective treatment for patients suffering from coronary artery disease.

In summary, the ScoreFlex NC PTCA Balloon is a highly specialized tool trusted by cardiologists to perform advanced coronary interventions, providing superior results in the treatment of complex coronary lesions and enhancing overall patient outcomes.



Advanced Scoring Technology

The ScoreFlex Nc incorporates an integrated spiral scoring element designed to modify and dilate challenging coronary lesions. This mechanism allows for controlled vessel expansion by focusing force along the vessel wall, which minimizes the risk of vessel trauma while improving lesion compliance and stent deployment outcomes.


Low-Profile, Rapid Exchange Design

Engineered with a low crossing profile and rapid exchange shaft, the ScoreFlex Nc ensures easy navigation and access to tight or complex lesions. It is compatible with 0.014-inch guidewires and features dual platinum-iridium marker bands, allowing for precise balloon placement under fluoroscopic guidance.


Reliable and Safe Performance

Made from high-strength, non-compliant Nylon, the ScoreFlex Nc can reach a rated burst pressure of up to 20 atm, ensuring minimal dilation beyond rated size. EO sterilization and individual packaging guarantee safety, while a shelf life of 2-3 years provides long-term reliability for clinical inventory.

FAQ's of ScoreFlex Nc Ptca Balloon:


Q: How is the ScoreFlex Nc PTCA Balloon Catheter used during coronary angioplasty?

A: The ScoreFlex Nc is introduced into the coronary artery using a compatible 0.014-inch guidewire. Its low-profile, rapid exchange design lets clinicians navigate complex or tight lesions efficiently. Once at the target site, the spiral scoring element enables controlled lesion modification and dilatation prior to stent placement.

Q: What are the key benefits of the integrated spiral scoring wire?

A: The integrated spiral scoring wire enhances lesion modification by concentrating force along the vessel wall, thus enabling precise dilatation and improving preparation for stent deployment. This reduces the risk of plaque slippage and vessel injury compared to conventional balloon angioplasty.

Q: When should a non-compliant balloon like ScoreFlex Nc be selected?

A: A non-compliant balloon such as the ScoreFlex Nc is ideal for fibrous or calcified lesions and situations where predictable, minimal dilation is required. Its high-pressure tolerance and controlled compliance make it an excellent choice for lesion preparation before stenting.

Q: Where can the ScoreFlex Nc be stored prior to use?

A: Store the ScoreFlex Nc in a cool, dry place within its individually packed, sterile pouch. Ensure it remains unopened and away from excessive moisture or heat to preserve the device's sterility and effectiveness throughout its 2-3 year shelf life.

Q: What is the process of balloon inflation and deflation with ScoreFlex Nc?

A: The ScoreFlex Nc is manually operated using a standard inflation device through its universal Luer Lock connector. Inflation should not exceed the rated burst pressure of 20 atm, and deflation is performed promptly after dilatation to facilitate safe retrieval from the vessel.

Q: Is the ScoreFlex Nc suitable for single-use only?

A: Yes, the ScoreFlex Nc PTCA Balloon Catheter is intended for disposable, single-use applications to ensure sterility and minimize the risk of cross-contamination between patients.

Q: What is the measurement range available for the ScoreFlex Nc PTCA Balloon?

A: The ScoreFlex Nc is available in balloon diameters ranging from 1.50 mm to 4.00 mm and lengths from 6 mm to 30 mm, accommodating a broad scope of interventional requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Skin Care Products Category

ABBOTT MINI TREK RX CORONARYDILATION CATHETER

ABBOTT MINI TREK RX CORONARYDILATION CATHETER

Price 8000 INR / Pack

Minimum Order Quantity : 100 Packs

Condition : Other, Sterile, Singleuse

Color : Transparent/Clear with colored markers

Storage Instructions : Store in cool, dry place, avoid direct sunlight

Function : Dilating stenotic coronary arteries

Theophylline & Salbutamol Tablets 100/2mg

Theophylline & Salbutamol Tablets 100/2mg

Price 160 INR / Pack

Minimum Order Quantity : 100 Packs

Condition : New

Color : White

Storage Instructions : Store in a cool, dry place below 25C

Function : Relief from bronchospasm

Diclofenac Sodium & Paracetamol Tablets 50/500mg

Diclofenac Sodium & Paracetamol Tablets 50/500mg

Price 650 INR / Pack

Minimum Order Quantity : 100 Packs

Condition : New

Color : White

Storage Instructions : Store in a cool, dry place below 25C, protect from light

Function : Relief from mild to moderate pain and inflammation

Coloplast Clamp 9503

Coloplast Clamp 9503

Price 100 INR / Piece

Minimum Order Quantity : 100 Pieces

Condition : New

Color : White with blue accents

Storage Instructions : Store in a cool, dry place away from direct sunlight

Function : Controls urine leakage by gentle pressure on the urethra