Ophthalmic Machine Lensmeter
Ophthalmic Machine Lensmeter Specification
- Temperature Range
- 10C - 40C
- Material
- Metal and Plastic Construction
- Weight
- Around 3.5 kg
- Suitable For
- Optometrists, Ophthalmologists, Optical Shops, Labs
- Frequency
- 50 Hz
- Humidity Range
- 10% - 85% RH
- Height
- Approx. 410 mm
- Product Type
- Ophthalmic Machine Lensmeter
- Properties
- Precision optics, easy calibration, stable measurement
- Display Type
- Analog
- Shape
- Vertical Instrument Format
- Power
- AC Powered
- Phase
- Single Phase
- Application
- Measurement and verification of ophthalmic lenses
- Treatment Type
- Diagnostic / Measurement
- Accuracy
- 0.12 D
- Dimension (L*W*H)
- Approx. 200 x 320 x 410 mm
- Use
- Hospital
- Color Code
- White
- Automation Grade
- Manual
- Function
- Measures sphere, cylinder, axis, and add power
- Power Source
- Electric (AC Mains)
- Display
- Analog Dial
- Voltage
- 220 V
- Lens Power Measurement Range
- -25D to +25D
- Measurement Accuracy
- High repeatability, objective scale
- Measurement Type
- Single and progressive lens capability
- Lens Diameter Range
- 20 mm to 90 mm
- Focusing Mechanism
- Coarse and fine adjustment knobs
- Scale Reading
- Clear, easy-to-read analog scale
- Prism Measurement Range
- 0 - 5 Prism Diopters
- Light Source
- LED Illumination
- Eyepiece Adjustment
- 5 D (Diopters)
- Lens Table
- Tiltable, anti-slip platform for secure lens positioning
- Safety Features
- Overload protection, non-slip base
Ophthalmic Machine Lensmeter Trade Information
- Minimum Order Quantity
- 100 Pieces
- Supply Ability
- 200 Pieces Per Day
- Delivery Time
- 2 Days
About Ophthalmic Machine Lensmeter
Extensive Application Versatility for the Lensmeter
Area of application for the Ophthalmic Machine Lensmeter includes precise measurement and verification of ophthalmic lenses in both diagnostic and quality control scenarios. Application media encompasses single vision, bifocal, and progressive lenses. Application places span hospitals, optical shops, vision laboratories, and ophthalmology practices. This flexibility ensures the lensmeter caters to the diverse needs of healthcare providers, vision specialists, and medical device exporters throughout India, delivering reliable results wherever optical measurement is required.
Certifications, Market Coverage, and Rapid Delivery Assured
The Ophthalmic Machine Lensmeter is supplied with quality certifications, ensuring compliance and safety. With a primary focus on the main domestic market throughout India, customers benefit from streamlined logistics and quick dispatch capabilities. Safe transportation and careful drop-off are a priority, guaranteeing the product reaches you promptly and intact. Ongoing support from manufacturers, suppliers, and exporters further ensures you receive your lensmeter on time, ready for immediate integration into your practice or facility.
FAQ's of Ophthalmic Machine Lensmeter:
Q: How does the lensmeter ensure high measurement accuracy?
A: The Ophthalmic Machine Lensmeter features precision optics, an objective analog scale, high repeatability, and easy calibration, all of which combine to deliver measurement accuracy up to 0.12 D for reliable results.Q: What types of lenses can be measured using this lensmeter?
A: This machine accommodates single vision, bifocal, and progressive lenses with a diameter range of 20 mm to 90 mm and measures lens powers from -25D to +25D for versatile ophthalmic applications.Q: Where is the Ophthalmic Machine Lensmeter most commonly used?
A: It is widely used in hospitals, optometrist offices, ophthalmology clinics, optical shops, and specialized vision laboratories for diagnostic and measurement tasks.Q: When can customers expect delivery of their lensmeter orders?
A: With a focus on the main domestic market, the manufacturer provides quick dispatch and secure transportation, ensuring prompt drop-off and delivery, generally within the stipulated shipping timeframe provided during order placement.Q: What safety features does this lensmeter include?
A: The instrument incorporates overload protection and a non-slip base to guarantee safe, stable operation during lens measurement and calibration processes.Q: How do I maintain the matchless performance of the lensmeter?
A: Regular cleaning, proper calibration, and adherence to manufacturer guidelines will uphold the lensmeter's unassailable accuracy and ensure long-lasting, valiant performance in your practice.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Ophthalmic Machine Category
Ophthalmic Machine With Scan Biometer
Minimum Order Quantity : 100 Pieces
Height : 300 mm
Humidity Range : 30% 85% (noncondensing)
Properties : Noncontact, High Precision, Integrated System
Product Type : Ophthalmic Machine
Shape : Rectangular
Yag Laser Ophthalmic Machine
Minimum Order Quantity : 100 Pieces
Height : 60 cm
Humidity Range : 10%80% RH
Properties : Precise Laser Delivery, Compact Design, High Reliability
Product Type : Ophthalmic Machine
Shape : Rectangular
Cryo Ophthalmic Machine
Minimum Order Quantity : 100 Pieces
Height : 150 mm
Humidity Range : 35% to 90% noncondensing
Properties : Portable, highprecision cooling, fast freezing action
Product Type : Cryo Ophthalmic Machine
Shape : Rectangular, compact
Ophthalmic Machine With Cryo Ophthalmic Unit
Minimum Order Quantity : 100 Pieces
Height : 255 mm
Humidity Range : 10% 90% RH
Properties : Portable, Highly Durable, Robust Construction
Product Type : Ophthalmic Machine
Shape : Rectangular Unit with Flexible Cryo Probe
![]() |
TABNCAP HEALTHCARE
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |